dBV, dBu, and dBm

I’ve always have a little trouble remembering the relationship between dBm and the more common signal measurements of dBu and dBV.  The other day I was looking at a transfer function, and I was given results in dBm - the impetus for this post.

First, I should make sure we’re all on the same page.  What is a decibel (dB)?  The decibel is a relative measurement.  For voltage we calculate dB as 20log10(Voltage/Reference), where the reference can be absolute (like with dBu and dBV) or relative (plain old dB).  For an amplifier that outputs a signal twice as large as the input, 20log10(2/1) = 6 .02 dB.  If we ran a signal through this amplifier twice, our output is 4 times as large as the input, or 20log10(4/1) = 12.04dB.  This is the value of a dB scale - we can add gain values in dB instead of multiplying them: 22=4, while 6.02+6.02=12.04.

Before going on I should point out that dBm is not an appropriate measure for a transfer function.  Straight dB is the way to go, as a linear transfer function should produce an output relative to the input - not relative to an absolute value like dBm, dBu, or dBV.  Let’s say I put 0.5 volts into a system, and I get 0.25 volts back out: 20*log10(0.25/0.5) = -6 dB.

So then dBV, dBu, and dBm are all absolute measurements and each has a defined reference value:

  • dBV - 1 Volt
  • dBu - 0.775 Volts
  • dBm - 1 Milliwatt

dBV is straight ahead and simple to work with - this is the measure I use most frequently.  The dBV value of any voltage is 20*log10(V/1), so 1 Volt is 0 dBV, 2 Volts is 6 dBV, and 0.5 Volts is -6 dBV.

Let’s skip to dBm for a second.  This has a reference of 1 milliwatt, a unit of power.  Power is related to voltage by the equation P = VV/R, where R is the resistance the power is dissipated through.  For instance, if I drive 1 Volt into 1000 Ohms of resistance, 1V1V/1000Ohms = 0.001 Watts = 1 mW.  If I increase the voltage by 6 dB (a factor of 2) to 2 Volts, now I’m dissipating 2V2V/1000Ohms = 4 mW.  This is important - doubling the voltage does not lead to a doubling of power, since the power is related to the square of the voltage.  We actually have to use a different formula for dB of power, 10log10(Power/Reference).  With this formula, if we put in our 4mW and 1mW from above, we still get 6 dB of gain.  Math works!

Back to dBu.  dBu is referenced to 0.775 Volts - an odd number to use as a reference.  However, if you calculate the power dissipating by 0dBu through 600Ohms (a long-standing common value for transmission lines), you wind up with exactly 1mW of power, 0dBm.  So 0dBu = 0dBm, if and only if the load is 600 Ohms.  At any other load impedance this relationship changes.

So back to that transfer function in dBm.  In order to get a relative dB measurement I needed two things: the source voltage and the load impedance.  Knowing the load impedance allows you to calculate the voltage output from the system: V = sqrt(PR).  This is still an absolute measurement, so you need to know what the input signal was to calculate the dB out: 20log10(Output/Input).

Your post must include a link to this post.

How does this work?
Write a response on your own website and include a link to this post. Then submit your response’s URL here. Your response may appear here after moderation. To update or remove it, edit or delete your original post and submit the same URL again. Learn more about Webmentions.